pyserial to read from DS1615 temperature recorder chip
Grant Edwards
grante at visi.com
Mon Jul 24 14:48:48 EDT 2006
More information about the Python-list mailing list
Mon Jul 24 14:48:48 EDT 2006
- Previous message (by thread): pyserial to read from DS1615 temperature recorder chip
- Next message (by thread): pyserial to read from DS1615 temperature recorder chip
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
On 2006-07-24, Gerhard Fiedler <gelists at gmail.com> wrote: > On 2006-07-24 14:03:30, alexandre_irrthum at yahoo.com wrote: > >> To read from the chip, one must issue the "read page" command (33h), >> followed by the two-byte address of the requested page (pages are 32 >> bytes long). After receiving this, the DS1615 will send the data in a >> burst of (up to) 32 bytes. > > I'm not sure what you mean when you say it will send "up to" 32 bytes. Registers are in 32-byte pages. If you request register N, the device sends register N followed by the remainder of the 32-byte page that contains address N. If you request the first register on a page, you'll get 32 bytes back. If you request the last register on a page, you'll get one 1 back. -- Grant Edwards grante Yow! If I pull this SWITCH at I'll be RITA HAYWORTH!! Or visi.com a SCIENTOLOGIST!
- Previous message (by thread): pyserial to read from DS1615 temperature recorder chip
- Next message (by thread): pyserial to read from DS1615 temperature recorder chip
- Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]