Gaussian
Three models of variogram were used in Kriging: Spherical, Exponential and Gaussian. It should be noted that the algorithms calculate the raster layer, considering all pixels within the rectangle defined by the latitudes and longitudes and may at times fall out of the intended Nigeria region.
Based on Gaussian mechanism, we generalize privacy budget [epsilon] [member of] (0,1) to [epsilon] > 0, such that the privacy budget has a widely range.
A GMM can be viewed as a weighted sum of several Gaussian distribution components, whose PDF, for one-dimensional case, can be defined as [23]
2 shows the peak value of spectra (1) and pulses (2) for initial Gaussian (a) and secant-hyperbolic (b) pulses, which shows that the process has a periodic character not only for Gaussian pulses but also for secant-hyperbolic pulses.
A Gaussian Membership function is specified by two parameters: a Gaussian membership function is determined complete by [mu] and [sigma]; [mu] represents the membership ship center (the peak of the curve) and [sigma] determines the membership function width.
In [18], a sequential one-dimensional searching (SOS) algorithm is proposed for Gaussian CD sources using a pair of uniform circular arrays, which first estimates the nominal elevation by the TLS-ESPRIT method, followed by sequential one-dimensional searching to seek the nominal azimuth.
In the large N limit, for the Gaussian model, the resolvent obeys the self-consistency equation (also known as the Schwinger-Dyson equation) (see, e.g., [10], Section VII.4):
Here, we choose the spheroid to represent the nonspherical mineral aerosol in order to study the scattering cross sections of nonspherical particles within the Gaussian beam incidence.
(i) As indices, i stands for a user particle, j denotes a transmitter or a signal component, l is a component in a Gaussian mixture model, and m stands for a sigma point.
The different types of filtering technique include average, disk, mean median, Gaussian, Laplacian, motion, Perwitt, Sobel, Median and Adaptive Median filter.
Since a closed form solution to the Bayesian recursive estimation is available only for a few special cases [3], such as the linear Gaussian system (which leads to the classical standard Kalman filter), a suboptimal solution is a preferable choice in the general case [4, 5].
In the article titled "A Theoretical Argument Why the t-Copula Explains Credit Risk Contagion Better than the Gaussian Copula" [1], the name of the fourth author was given incorrectly as Satjaporn Tungsong.
As illustrated in Figure 1, the fluorescence, F, generated at a plane, z, would be more confined to the focal plane when using an annular laser beam when compared to Gaussian beam illumination.